+86 13587807973

Power Transmission

  • RW12 series 11KV Drop out Fuse
  • RW12 series 11KV Drop out Fuse

RW12 series 11KV Drop out Fuse

Drop-out fuses and pull-down fuses are outdoor high-voltage protection appliances.

Drop-out fuses and pull-down fuses are outdoor high-voltage protection appliances. It is installed on the high voltage side of the distribution transformer or on the branch line of the distribution line. It is used as short circuit, overload protection and split and combined load current of the transformer and line. The Drop-out fuse consists of two parts: an insulating bracket and a fuse tube.The static contact is installed at both ends of the insulating bracket, the movable contact is installed at both ends of the fuse tube, and the fuse tube is composed of the arc extinguishing tube of the inner layer and the phenolic paper tube or the epoxy glass tube of the outer I aye r. Control load Drop-out fuse enhanced auxiliary contact and arc extinguishing cover, which is used to split and combined load current.

Drop-out fuses and pull-down fuses is installed on the high voltage side of the distribution transformer or on the branch line of the distribution line. This 11kv drop out fuse is used as short circuit, overload protection and split and combined load current of the transformer and line. The Drop-out fuse consists of two parts: an insulating bracket and a fuse tube.The static contact is installed at both ends of the insulating bracket, the movable contact is installed at both ends of the fuse tube, and the fuse tube is composed of the arc extinguishing tube of the inner layer and the phenolic paper tube or the epoxy glass tube of the outer I aye r. Control load Drop-out fuse enhanced auxiliary contact and arc extinguishing cover, which is used to split and combined load current. When the 11kv drop out fuse is in normal operation, the fuse tube is tensioned by the fuse to form a closed position .When the system fails, the fault current causes the fuse to melt quickly and form an arc. The arc extinguishing tube is heated by the arc, decomposing a large amount of gas, forming a high pressure inside the tube, forming a longitudinal blow along the pipe, and the arc is rapidly elongated and extinguished .After the fuse being blown, the lower moving contact loses tension and turns down, locking the initial machine, releasing the fuse tube, and the fuse tube falling, forming an obvious breaking position.When the load needs to be pulled, use the insulation rod to pull the movable contact.At this time, the active and static contacts are still in contact, and the active and auxiliary contact is continued by the insulating rod, and an arc is generated between the auxiliary contacts, the arc elongated in the slit of the shield, and the arc extinguishing cover being generated the gas, which extinguishes the arc when the current crosses zero.

NO.Description
1Back Plate
2Long Bolts
3Mouting Brackets
4Porcelain
5Cannector
6Upper Housing
7Upper Contacts
8Attachment Hooks
9Operation Ring
10Fuse Tube
11Toggle Joint
12Lower Housing

Fuse Link …“KB、KU、KS” type

Types and Applications
“KB, KU, KS”type belong to”K”and”T”type fuse links. According to I EC-282 standard, there are three types: common type, universal type and threaded type. It is suitable for 11~33kV voltage class drop-out fuse.

Technical data

Rated current (ADimensions (mm)Quantity
carton
ABCDF
1 to 2512.5±0.219.0±0.2Note 12.06.5500
30 to 4012.5±0.219.0±0.2Note 13.08.0500
50 to 10019.0±0.3Not applicableNote 15.010.0250
140 to 20019.0±0.3Not applicableNote 17.012.0150

Fuse link selection

Transformer capacity (kVA)Rated current (A)Fuse link specifications
100.583
201.153
301.733~5
502.895~10
633.647.5~10
804.6210~15
1005.7710~15
1257.2215~20
1609.2415~20
20011.5520
31518.1930

Structure size

Order information


1. Product model, name, rated voltage, rated current, and rated breaking current;

2. Environmental requirements (anti-pollution type, highland type);
3. Special requirements can be talked with the manufacturer.

RW12-11KV drop-out fuse (Export-type)

ModelRated voltage
(kV)
Rated current
(A)
Breaking current
(kA)
Impulse voltage
(BIL)
Power frequency
withstand voltage
(kV)
Creepage
distance(mm
Weight (kg)Outline
Dimensions
(cm)
(H)RW12-12/1001210012.511038(400)216(3.4)5.841x38x10
(H)RW12-12/200122001611038(400)216(3.6)641x38x10

Drop-out fuse Installation diagram (Export-type)

Drop-out fuse mounting bracket (Export-type)

CONTACT US
Copyright © 2007-2024 Delixi Electric All Rights Reserved.    浙ICP备13001006号-1  浙ICP备13001006号-3  Sitemap

LEAVE A MESSAGE

Contact us!
We're not around but we still want to hear from you! Leave us a note:

* indicates a required field