CDQ3H-B type CB Class Automatic transfer switch,4 pole automatic transfer switch,automatic transfer switch double,automatic transfer switch generator,automatic transfer switch generators,automatic transfer switch pakistan,ATS,CDQ3H-B type CB Class Automatic transfer switch - 3/4 Phase| DELIXI,double power auto transfer switch, 3 phase automatic transfer switch, 4 pole automatic transfer switch, manufacturer, supplier.,CDQ3H-B type Automatic transfer switch supply, the main power off, it can automatic transfer to generator, and the main power is restored, it will transfer to main power. Network frequency: 50 Hz, rated operational current: 10-315A.,DZ47sLE Residual current operated circuit breaker,rccb operation,residual current circuit breaker,residual current circuit breaker breaker,residual breaker circuit breaker,nfin residual current circuit breaker,MCB,DZ47sLE Residual current operated circuit breaker | DELIXI,residual current circuit breaker, rcb circuit breaker, manufacturer, supplier.,DZ47sLE Current residual current operated circuit breaker Supply, The shell and parts are made of high flame retardant and shock resistant plastics, and have a long service life. supports short circuit and overload protection. Suitable for home decoration, engineering construction, rural network transformation

Welcome to the DELIXI Website

0
33kv power transformer

SZ11-33kV Series Power Transformer

SZ11-33kV
Quantity
Contact Now
add to cart

33kV Series Power Transformer

33KV power distribution transformers
Product Features

1.These types of power distribution transformers have High Efficiency, Low Loss, Low Noise Characters

2. Good Inside Heat Emission, High Anti Short Circuit, Safe And Reliable

3. Empty, Load Loss Is Low

4. Reliable, long service life, free maintenance.

Transformer Standards

GB 1094.1-1996 GB 1094.2-1996

GB 1094.3-2003 GB/T 7595-2008

GB/T 6451-2008 JB/T 3837-2010

Transformer Special Service Conditions

1. The height above sea level is above 1000m
2. Ambient temperature
3. Highest air temperature is above 40°C
4. Lowest air temperature Lower than 45°C (defines in detail when placing an order)

Transformer Normal Service Conditions
1 The height above the sea level is below 1000m

2 Ambient temperature:
■ Highest air temperature +40°C
■ Highest daily average air temperature+30°C

■ Highest annual average air temperature +20°C

■ Lowest outdoor air temperature -25°C

Transformer Model Description

types of power distribution transformers manufacturers

S11 Series 33kV Distributtion Transformer
50KVA-1600KVA 3-Phase Duplex Winding Off-load Tap-Changing Distribution Transformer

S11 Series 33kV distributtion transformer

Note
1. Rated capacity 500KVA and below transformer, the load loss above the oblique line in the table applies to Dyn11 or Yzn11; the load loss below the oblique line applies to Yyn0.
2. According to requirements, this 33kv transformer can supply HV tap change ± 2x 2.5%.

630KVA-31500KVA Triple Phase Duplex Winding Non Off-load Regulating Power Transformer

630KVA-31500KVA Triple Phase Duplex Winding Non Off-load Regulating Power Transformer

SZ11 Series 33kV Power Transformer
2000KVA-20000KVA 3-Phase Duplex Winding Off-load Tap-Changing Power Transformer

SZ11 Series 33kV power transformer